MySpot 200 Diagnostics Wizard

 Page 22


The barrier responds to a command but falls all the way to the ground (Overtravel state). It should stop at about 100 mm (4") off the ground (Unlocked State).

One likely cause for this problem is a failure in the torque clutch that is located in the PowerPod Cowling. Another is that the slide latch does not lock the slide properly.

The States of the barrier


The cowling holds the torque clutch


Post 51


Spring 24


  1   How to determine if the torque clutch is broken (when done, remember to return to page "22") 

  2   How to open the PowerPod. Remember to proceed with "problem 22". 

  3   Post 51 is loose 

  4   Spring 24 jumped out of its place 

  5   Worn or defective latch 50 

  6   Loose guide screws 23 

  7   Worn or defective slide 6 

  8   None of the above